21
© 2003 directed electronics, inc.
type C: direct-wired, reversing-polarity system
testing reversing polarity systems
Use these instructions if the power door lock switch has four or
five heavy-gauge wires. This type of switch has two outputs that
rest at (-) ground.
important: To interface with these systems, you must cut
two switch leads. The relays must duplicate the factory
door lock switches’ operation. The master switch will
have one or two ground inputs, one (+)12V input, and
two switch outputs going directly to the slave switch and
through to the motors. These outputs rest at (-) ground.
The lock or unlock wire is switched to (+)12V, while the
other wire is still grounded, thus completing the circuit
and powering the motor. This will disconnect the switch
from the motor before supplying the motor with (+)12V,
avoiding sending (+)12V directly to (-) ground.